Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Inst Mech Eng H ; 238(3): 348-357, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38279687

RESUMO

This study focuses on novel design and evaluation of Elastic 50A (EL50) mechanical metamaterials with open-cell patterns for its potential application to lower limb residuum/socket interfaces, specifically that of a transtibial (TT) amputee. Mechanical characteristics, that is, effective Young's modulus (E), was tuned by altering metamaterial porosity, which was experimentally verified. Specifically, pore radius of the unit cell was varied to achieve a range of E-values (0.05-1.71 MPa) for these 3D printed metamaterials. Finite Element Analysis (FEA) was conducted to evaluate pressure distribution across key load-bearing anatomical sites of a TT residuum. Using designed metamaterials for homogeneous liners, pressure profiles were studied and compared with a silicone liner case. Additionally, a custom metamaterial liner was designed by assigning appropriate metamaterials to four load-sensitive and tolerant anatomical sites of the TT residuum. The results suggest that lowest pressure variation (PV), as a measure of pressure distribution levels and potential comfort for amputees, was achieved by the custom metamaterial liner compared to any of the homogeneous liners included in this study. It is envisaged that this work may aid future design and development of custom liners using now commonly available 3D printing technologies and available elastomer materials to maximise comfort, tissue safety and overall rehabilitation outcomes for lower limb amputees.


Assuntos
Amputados , Membros Artificiais , Humanos , Amputados/reabilitação , Desenho de Prótese , Resultado do Tratamento , Silicones
2.
Clin Biomech (Bristol, Avon) ; 112: 106178, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38232471

RESUMO

BACKGROUND: Cervical collars restrict cervical spine movement to minimise the risk of spinal cord injury. Collars apply mechanical loading to the skin putting it at risk of skin damage. Indeed, cervical collar-related pressure ulcers are unacceptably prevalent, especially at the occiput, mandibles, and chin. Collar design and fit are often key considerations for prevention. METHODS: This comprehensive study evaluated four commercial prehospital and acute care cervical collars. Pressure, microclimate, transepidermal water loss and skin hydration were measured at the interface between the device and the skin. Range of motion restriction was measured to evaluate effective immobilisation. Head, neck, and shoulder morphology was evaluated using three-dimensional scans. FINDINGS: The occiput experienced significantly higher interface pressures than the chin and mandibles for most collar designs. Interface pressure at the occiput was significantly higher for the Stiffneck extrication collar compared to the other collar designs. The Stiffneck collar also provided the most movement restriction, though not significantly more than other designs. Relative humidity at the device skin interface was significantly higher for the Stiffneck and Philadelphia collars corresponding to closed cell foam padding, in contrast to the open cell foams lined with permeable fabric used in the other collars. Collar discomfort correlated with both occipital pressure and skin humidity. INTERPRETATION: The occiput is at increased risk of cervical collar-related pressure ulcers during supine immobilisation, especially for Stiffneck extrication collars. Lined open-cell foams could be used to minimise skin humidity and increase comfort.


Assuntos
Lesão por Pressão , Humanos , Lesão por Pressão/prevenção & controle , Lesão por Pressão/etiologia , Contenções , Pescoço , Vértebras Cervicais/lesões , Bioengenharia , Imobilização/efeitos adversos
3.
J Wound Care ; 32(9): 587-596, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37682784

RESUMO

OBJECTIVE: To investigate reliability and changes of in-shoe plantar pressure and shear during walking at three cadences with two insole designs. This was a precursor to the investigation of plantar loading in people with diabetes for potential foot ulcer prevention. METHOD: A sensorised insole system, capable of measuring plantar pressure and shear at the heel, fifth metatarsal head (5MH), first metatarsal head (1MH) and hallux, was tested with ten healthy participants during level walking. Reliability was evaluated, using intra-class correlation coefficient (ICC), while varying the cadences and insole types. Percentage changes in pressure and shear relative to values obtained at self-selected cadence with a flat insole design were investigated. RESULTS: Mean±standard deviation of maximum pressure, medial-lateral and anterior-posterior shear of up to 380±24kPa, 46±2kPa and -71±4kPa, respectively, were measured. The ICC in ranges of 0.762-0.973, 0.758-0.987 and 0.800-0.980 were obtained for pressure, anterior-posterior and medial-lateral shear, respectively. Opposite anterior-posterior shear directions between 5MH and 1MH (stretching), and between 1MH and hallux (pinching) were observed for some participants. Increasing cadence increased pressure and anterior-posterior shear (by up to +77%) but reduced medial-lateral shear at the heel and hallux (by up to -34%). Slower cadence increased anterior-posterior shear (+114%) but decreased medial-lateral shear (-46%) at the hallux. The use of a flexible contoured insole resulted in pressure reduction at the heel and 5MH but an increase in anterior-posterior shear at the heel (+69%) and hallux (+75%). CONCLUSION: The insole system demonstrated good reliability and is comparable to reported pressure-only systems. Pressure measurements were sensitive to changes in cadence and insole designs in ways that were consistent with the literature. However, our plantar shear showed localised shear changes with cadences and insoles for the first time, as well as stretching and pinching effects on plantar tissue. This opens new possibilities to investigate plantar tissue viability, loading characteristics and orthotic designs aimed towards foot ulcer prevention.


Assuntos
Diabetes Mellitus , Pé Diabético , Humanos , Pé Diabético/prevenção & controle , Reprodutibilidade dos Testes , Sapatos , Voluntários Saudáveis , Caminhada
4.
Appl Bionics Biomech ; 2023: 3257059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37621485

RESUMO

Fluctuations in residuum volume during daily activities are known to occur in lower-limb amputees. This can cause frequent changes to fit, which cannot be accommodated by commonly-used prosthetic sockets. The real-time effects, if any, of these minor socket fit changes on interface biomechanics have not been studied extensively. Amputees commonly use different layers of socks to accommodate frequent volume fluctuations, enabling adjustment of socket fit. We, thus, altered socket fit levels via addition/removal of sock layers to a transtibial amputee who habitually-donned two-sock layers to mimic relatively looser and tighter socket fits. Interface pressure and shear sensors were placed at known prominent load-bearing sites of the transtibial residuum/socket interface, i.e., patellar tendon (PT), popliteal fossa (PF), and anterior-distal (AD) end, to measure real-time biomechanical interactions during standing and level walking. Although socket fit level was only slightly modified, changes in interface pressure and shear across anatomical sites were still observed. Tighter fit corresponds to notable pressure reduction at AD during early stance and pressure increase at PT during terminal stance due to the residuum being pushed up. Shear-to-pressure ratios were used to assess comfort, while pressure- and shear-time integrals were used to assess tissue health. We observed more notable changes at tissue sites (e.g., AD and PF). Combined evaluation of pressure and shear, including shear-to-pressure ratio and time integrals, may offer insight for residuum care.

5.
Sensors (Basel) ; 23(15)2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37571655

RESUMO

Commercial pressure monitoring systems have been developed to assess conditions at the interface between mattress/cushions of individuals at risk of developing pressure ulcers. Recently, they have been used as a surrogate for prolonged posture and mobility monitoring. However, these systems typically consist of high-resolution sensing arrays, sampling data at more than 1 Hz. This inevitably results in large volumes of data, much of which may be redundant. Our study aimed at evaluating the optimal number of sensors and acquisition frequency that accurately predict posture and mobility during lying. A continuous pressure monitor (ForeSitePT, Xsensor, Calgary, Canada), with 5664 sensors sampling at 1 Hz, was used to assess the interface pressures of healthy volunteers who performed lying postures on two different mattresses (foam and air designs). These data were down sampled in the spatial and temporal domains. For each configuration, pressure parameters were estimated and the area under the Receiver Operating Characteristic curve (AUC) was used to determine their ability in discriminating postural change events. Convolutional Neural Network (CNN) was employed to predict static postures. There was a non-linear decline in AUC values for both spatial and temporal down sampling. Results showed a reduction of the AUC for acquisition frequencies lower than 0.3 Hz. For some parameters, e.g., pressure gradient, the lower the sensors number the higher the AUC. Posture prediction showed a similar accuracy of 63-71% and 84-87% when compared to the commercial configuration, on the foam and air mattress, respectively. This study revealed that accurate detection of posture and mobility events can be achieved with a relatively low number of sensors and sampling frequency.


Assuntos
Postura , Lesão por Pressão , Humanos , Redes Neurais de Computação , Leitos , Voluntários Saudáveis
6.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991838

RESUMO

Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial-lateral and anterior-posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.


Assuntos
Diabetes Mellitus , Pé Diabético , Órtoses do Pé , Dispositivos Eletrônicos Vestíveis , Humanos , Pé Diabético/diagnóstico , Pé Diabético/prevenção & controle , , Sapatos , Pressão
7.
Proc Inst Mech Eng H ; 236(9): 1349-1356, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35821656

RESUMO

The study was designed to establish a biomechanical assessment platform for the lower limb residuum/socket interface as a function of duration and speed of movement. The approach exploits an interface sensor which measures multi-directional stresses at the interface. The corresponding interface coupling motion was assessed using a 3D motion capture system. A longitudinal study, involving a trans-femoral amputee, was conducted with nine repeated level walking sessions over a 12-month period. The effect of walking speed on interface biomechanics was also assessed. Interface peak pressures and shear stresses in the range of 55-59 kPa and 12-19 kPa were measured, respectively, over all sessions in the 12 months study period at the posterior-proximal location of the residuum. The peak pressure and longitudinal shear values were found to fluctuate approximately 11% and 40% as against its maximum value, respectively, over 12 months. In addition, up to 12° of angular coupling and up to 28 mm of pistoning were recorded over a gait cycle, which was found to change by 29% and 45% respectively over the study period. The variation in walking speed, by altering self-selected cadence, resulted in changes of pressure and shear stresses at mid-stance of the gait cycle. In particular, as compared with self-selected cadence, for fast speed, peak pressure and peak longitudinal shear stress decreased by 5% and 33%, respectively. For slow speed, peak pressure and peak longitudinal shear stress increased by 7% and 17%, respectively. The corresponding angular and pistoning revealed a variation of up to 29% and 45%, respectively. This biomechanical assessment approach shows promise in the quantitative assessment of interface kinematics and kinetics for lower limb prosthetics, the usage of which could assist the clinical assessment of prosthetic socket fit.


Assuntos
Amputados , Membros Artificiais , Cotos de Amputação , Fenômenos Biomecânicos , Marcha , Humanos , Estudos Longitudinais , Extremidade Inferior , Desenho de Prótese
8.
Nanoscale ; 11(25): 12370-12380, 2019 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-31215940

RESUMO

We report the self-assembly of an extensive inter-ligand hydrogen-bonding network of octylphosphonates on the surface of cesium lead bromide nanocrystals (CsPbBr3 NCs). The post-synthetic addition of octylphosphonic acid to oleic acid/oleylamine-capped CsPbBr3 NCs promoted the attachment of octylphosphonate to the NC surface, while the remaining oleylammonium ligands maintained the high dispersability of the NCs in non-polar solvent. Through powerful 2D solid-state 31P-1H NMR, we demonstrated that an ethyl acetate/acetonitrile purification regime was crucial for initiating the self-assembly of extensive octylphosphonate chains. Octylphosphonate ligands were found to preferentially bind in a monodentate mode through P-O-, leaving polar P[double bond, length as m-dash]O and P-OH groups free to form inter-ligand hydrogen bonds. The octylphosphonate ligand network strongly passivated the nanocrystal surface, yielding a fully-purified CsPbBr3 NC ink with PLQY of 62%, over 3 times higher than untreated NCs. We translated this to LED devices, achieving maximum external quantum efficiency and luminance of 7.74% and 1022 cd m-2 with OPA treatment, as opposed to 3.59% and 229 cd m-2 for untreated CsPbBr3 NCs. This represents one of the highest efficiency LEDs obtained for all-inorganic CsPbBr3 NCs, accomplished through simple, effective passivation and purification processes. The robust binding of octylphosphonates to the perovskite lattice, and specifically their ability to interlink through hydrogen bonding, offers a promising passivation approach which could potentially be beneficial across a breadth of halide perovskite optoelectronic applications.

9.
Prosthet Orthot Int ; 42(1): 60-65, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28856964

RESUMO

BACKGROUND: Our hands constantly handle objects throughout our lives, where a crucial component of this interaction is the detection of grasping (pressure) and slipping (shear) of the object. While there have been a large amount of studies using pressure sensors for grasping detection, synchronised pressure and shear detection at the finger/object interface is still needed. OBJECTIVES: This study aims to assess the feasibility of a sensor system designed to detect both pressure and shear at the fingertip/object interface via a single subject test. STUDY DESIGN: Descriptive study, proof of concept. METHODS: One healthy subject participated in the study and was asked to perform a single finger test protocol and a simple hand test protocol. The corresponding multidirectional loads at the fingertip/object interface were measured in real time using a pressure and shear sensor system. RESULTS: Results from the finger test protocol show peak values of up to approximately 50 kPa (5 N) and 30 kPa (3 N) of pressure for each test, respectively. Results from the hand test protocol show a pressure and shear profile that shows a large increase in grip force during the initial grasping of the object, with a peak pressure of approximately 50 kPa (5 N). The pressure and shear profile demonstrates that the load is not evenly distributed across all digits. CONCLUSION: This study provides evidence that the reported sensor system has sufficient resolution, dynamic response and load capability to capture biomechanical information during basic protocols and hand-grasping tasks. Clinical relevance The presented sensor system could be potentially used as a tool for measuring and evaluating hand function and could be incorporated into a prosthetic hand as a tactile feedback system.


Assuntos
Retroalimentação Sensorial/fisiologia , Dedos/fisiologia , Força da Mão/fisiologia , Tato/fisiologia , Adulto , Membros Artificiais , Estudos de Viabilidade , Humanos , Cinética , Masculino , Pressão , Desenho de Prótese , Reprodutibilidade dos Testes
10.
Med Eng Phys ; 49: 131-139, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28927643

RESUMO

The bespoke interface between a lower limb residuum and a prosthetic socket is critical for an amputee's comfort and overall rehabilitation outcomes. Analysis of interface kinematics and kinetics is important to gain full understanding of the interface biomechanics, which could aid clinical socket fit, rehabilitation and amputee care. This pilot study aims to investigate the dynamic correlation between kinematic movement and kinetic stresses at the interface during walking tests on different terrains. One male, knee disarticulation amputee participated in the study. He was asked to walk on both a level surface and a 5° ramped surface. The movement between the residuum and the socket was evaluated by the angular and axial couplings, based on the outputs from a 3D motion capture system. The corresponding kinetic stresses at anterior-proximal (AP), posterior-proximal (PP) and anterior-distal (AD) locations of the residuum were measured, using individual stress sensors. Approximately 8° of angular coupling and up to 32 mm of axial coupling were measured when walking on different terrains. The direction of the angular coupling shows strong correlation with the pressure difference between the PP and AP sensors. Higher pressure was obtained at the PP location than the AP location during stance phase, associated with the direction of the angular coupling. A strong correlation between axial coupling length, L, and longitudinal shear was also evident at the PP and AD locations i.e. the shortening of L corresponds to the increase of shear in the proximal direction. Although different terrains did not affect these correlations in principle, interface kinematic and kinetic values suggested that gait changes can induce modifications to the interface biomechanics. It is envisaged that the reported techniques could be potentially used to provide combined kinematics and kinetics for the understanding of biomechanics at the residuum/socket interface, which may play an important role in the clinical assessment of prosthetic component settings, including socket fit quality.


Assuntos
Amputados , Desarticulação , Joelho/cirurgia , Fenômenos Mecânicos , Adulto , Fenômenos Biomecânicos , Marcha , Humanos , Cinética , Masculino , Projetos Piloto
11.
Proc Inst Mech Eng H ; 231(3): 235-242, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28164748

RESUMO

Mechanical coupling at the interface between lower limb residua and prosthetic sockets plays an important role in assessing socket fitting and tissue health. However, most research lab-based lower limb prosthetic simulators to-date have implemented a rigid socket coupling. This study describes the fabrication and implementation of a lower limb residuum/socket interface simulator, designed to reproduce the forces and moments present during the key loading phases of amputee walking. An artificial residuum made with model bones encased in silicone was used, mimicking the compliant mechanical loading of a real residuum/socket interface. A 6-degree-of-freedom load cell measured the overall kinetics, having previously been incorporated into an amputee's prosthesis to collect reference data. The developed simulator was compared to a setup where a rigid pylon replaced the artificial residuum. A maximum uniaxial load of 850 N was applied, comparable to the peak vertical ground reaction force component during amputee walking. Load cell outputs from both pylon and residuum setups were compared. During weight acceptance, when including the artificial residuum, compression decreased by 10%, while during push off, sagittal bending and anterior-posterior shear showed a 25% increase and 34% decrease, respectively. Such notable difference by including a compliant residuum further highlighted the need for such an interface simulator. Subsequently, the simulator was adjusted to produce key load cell outputs briefly aligning with those from amputee walking. Force sensing resistors were deployed at load bearing anatomic locations on the residuum/socket interface to measure pressures and were compared to those cited in the literature for similar locations. The development of such a novel simulator provides an objective adjunct, using commonly available mechanical test machines. It could potentially be used to provide further insight into socket design, fit and the complex load transfer mechanics at the residuum/socket interface, as well as to evaluate the structural performance of prostheses.


Assuntos
Membros Artificiais , Desenho de Prótese , Cotos de Amputação , Amputados , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Modelos Biológicos , Suporte de Carga
12.
ACS Nano ; 10(12): 11519-11524, 2016 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-28024385

RESUMO

Stiction is one of the major reliability issues limiting practical application of nano-electro-mechanical systems (NEMS), an emerging device technology that exploits mechanical movements on the scale of an integrated electronic circuit. We report on a discovery that stiction can be eliminated by infiltrating NEMS with nematic liquid crystals. We demonstrate this experimentally using a NEMS-based tunable photonic metamaterial, where reliable switching of optical response was achieved for the entire range of nanoscopic structural displacements admitted by the metamaterial design. Being a more straightforward and easy-to-implement alternative to the existing antistiction solutions, our approach also introduces an active mechanism of stiction control, which enables toggling between stiction-free and the usual (stiction-limited) regimes of NEMS operation. It is expected to greatly expand the functionality of electro-mechanical devices and enable the development of adaptive and smart nanosystems.

13.
Healthc Technol Lett ; 3(4): 280-283, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28008364

RESUMO

This Letter presents a capacitive-based sensor system for fingertip contact applications. It is capable of simultaneously measuring normal (pressure) and tangential (shear) stresses at the interface between a fingertip and external objects. This could be potentially exploitable for applications in the fields of upper limb prosthetics, robotics, hand rehabilitation and so on. The system was calibrated and its performance was tested using a test machine. To do so, specific test protocols reproducing typical stress profiles in fingertip contact interactions were designed. Results show the system's capability to measure the applied pressure and stresses, respectively, with high linearity between the measured and applied stresses. Subsequently, as a case study, a 'press-drag-lift' based fingertip contact test was conducted by using a finger of a healthy subject. This was to provide an initial evaluation for real-life applications. The case study results indicate that both interface pressure and shear were indeed measured simultaneously, which aligns well with the designed finger test protocols. The potential applications for the sensor system and corresponding future works are also discussed.

14.
Med Eng Phys ; 37(12): 1162-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26525779

RESUMO

Design and fitting of artificial limbs to lower limb amputees are largely based on the subjective judgement of the prosthetist. Understanding the science of three-dimensional (3D) dynamic coupling at the residuum/socket interface could potentially aid the design and fitting of the socket. A new method has been developed to characterise the 3D dynamic coupling at the residuum/socket interface using 3D motion capture based on a single case study of a trans-femoral amputee. The new model incorporated a Virtual Residuum Segment (VRS) and a Socket Segment (SS) which combined to form the residuum/socket interface. Angular and axial couplings between the two segments were subsequently determined. Results indicated a non-rigid angular coupling in excess of 10° in the quasi-sagittal plane and an axial coupling of between 21 and 35 mm. The corresponding angular couplings of less than 4° and 2° were estimated in the quasi-coronal and quasi-transverse plane, respectively. We propose that the combined experimental and analytical approach adopted in this case study could aid the iterative socket fitting process and could potentially lead to a new socket design.


Assuntos
Extremidade Inferior/fisiologia , Movimento , Desenho de Prótese/métodos , Adulto , Amputados , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...